BF376 C-TEC 24V 5A RELAY ON A PLATE

£10,000 inc. Vat: £10,000
  • A general purpose, double-pole, polarised 24V 5A relay designed for use in 24V fire alarm systems.
  • Incorporates a high intensity LED which illuminates red when the relay is active.
  • Can be connected to a suitable control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets, rollershutter doors, etc.
  • Can be mounted on 25mm flush or surface mount back boxes.

C-TEC 55000-122APO APOLLO SERIES 65 AIR HEAT DETECTOR

£10,000 inc. Vat: £10,000
A high-quality Type A1R static/rate of rise heat detector. Monitors temperature using a dual thermistor network which provides a voltage output proportional to the external air temperature. Certified to EN54-5 by the LPCB. Wide 9-33V DC operating voltage. Red LED illuminates when the detector is in alarm. Requires a 45681-201APO diode base, 45681-200APO non-diode base or 45681-245APO relay base.

C-TEC 55000-317APO APOLLO SERIES 65 OPTICAL SMOKE DETECTOR

£10,000 inc. Vat: £10,000
 
  • Wide operating voltage
  • Advanced electronic technology
  • Flashing LED option
  • Magnetic test switch option
  • Can be used on security systems
  • Electrically compatible with Series 60
  • Mechanically compatible with Series 60
  • Proven detection performance
  • Designed to meet approvals worldwide
  • Range of bases available
 

C-TEC 55000-600APO APOLLO XP95 OPTICAL SMOKE DETECTOR

£10,000 inc. Vat: £10,000
Fully compatible withC-TEC's XFP&ZFP XP95/Discovery Addressable Fire Panels. Works using the light scatter principle. Responds well to slow-burning, smouldering fires. Well-suited for bedrooms and escape routes. Red LED illuminates when the detector is in alarm. Certified to EN54-7 by the LPCB. Requires a 45681-210APO standard base or 45681-242APO low power relay base. 'Xpert' card addressed for speedy installation.

C-TEC C4403A2 ACTIV ATANDARD HEAT DETECTOR

£10,000 inc. Vat: £10,000
  • A high-quality Type A2 standard fixed temperature (60ºC) heat detector offering outstanding detection performance at a very competitive price.
  • Manufactured by C-TEC in the UK.
  • Third-party certified to EN54-5 by Intertek.
  • Wide 6-33V DC operating voltage.
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
  • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

C-TEC C4416 ACTIV OPTICAL SMOKE DETECTOR

£10,000 inc. Vat: £10,000
  • A high-quality optical smoke detector offering outstanding detection performance at a very competitive price.
  • Manufactured by C-TEC in the UK.
  • Third-party certified to EN54-7 by Intertek.
  • Wide 6-33V DC operating voltage.
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
  • Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels allowing a greater than 8 year life-span. 
  • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

C-TEC CFP702-2 ALARMSENSE 2 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
Two AlarmSensezone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators. Four conventional sounder circuits. Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system). Space for two x 12V 3.3Ah VRLA batteries.

C-TEC CFP702-4 STANDARD 2 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
Four conventional sounder circuits* Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors.

C-TEC CFP702E-4 ECONOMY 2 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Fouropen-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors

C-TEC CFP704-2 ALARMSENSE 4 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
FourAlarmSensezone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators. Four conventional sounder circuits. Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system). Space for two x 12V 3.3Ah VRLA batteries.

C-TEC CFP704-4 STANDARD 4 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
Four conventional sounder circuits. Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors.

C-TEC CFP704E-4 ECONOMY 4 ZONE CONVENTIONAL FIRE ALARM PANEL

£10,000 inc. Vat: £10,000
Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Fouropen-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors